Sensoray 2410 Manual do Utilizador Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 9
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 7
2410 Instruction Manual
6
Digital I/O Interface
4.2.1 External Relay Racks
The DIO connector pinout is compatible with a variety of solid
state relay racks (e.g., SSR-RACK08, SSR-RACK24 and
SSR-RACK48). However, there is no universal standard pinout
for relay racks, so before purchasing a rack you should verify
that it has a compatible pinout.
Most SSR racks include a terminal block, a Molex connector,
or both to connect 5VDC power to the rack. The 2410 module
provides 5VDC for this purpose on its AUX power connector
(see Figure 2).
4.2.2 Sensoray 2410TA Termination Board
On the 2410TA board, each DIO has two terminal block
connections: the active-low DIO signal (marked “-”) and +5V
(marked “+”). When a channel is functioning as an output,
these two terminals may be connected to a load as shown in
Figure 4.
Figure 4: Recommended Output Wiring
The load impedance must be high enough to limit DIO current
to its maximum allowed value. See page 7 for details.
If the load is inductive (e.g., a mechanical relay), a protection
diode should be added across the load to suppress induced
EMF that might otherwise damage the DIO circuitry.
When a channel is operating as an input (e.g., hard contact), the
active-low input signal is connected as shown in Figure 5.
Figure 5: Recommended Input Wiring
17 DIO47 42 DIO22
18 DIO46 43 DIO21
19 DIO45 44 DIO20
20 DIO44 45 DIO19
21 DIO43 46 DIO18
22 DIO42 47 DIO17
23 DIO41 48 DIO16
24 DIO40 49 NC
25 DIO7 50 GND
Table 3: DIO Connector Pinout
Pin Signal Pin Signal
+
-
2410TA
+
-
Load
+
-
2410TA
NC
GND
Vista de página 7
1 2 3 4 5 6 7 8 9

Comentários a estes Manuais

Sem comentários