Proceed to step 2 without cycling the power (while the unit is still in configuration
mode).
Step 2 – Set up a permanent IP address
Connect to the unit with a Web browser by typing the unit's temporary IP address in the
address box.
Examples:
http://192.168.24.24/network.htm
or
http://10.135.1.61/network.htm
The the network configuration page (Fig.5) will be displayed.
Type in the desired permanent IP address and subnet mask values into corresponding
fields. Click on the Set button and wait for the page to reload. Click on Reboot button.
The unit will reboot with a new IP address, so the current browser session will
disconnect. To continue configuration, type in the new, permanent address in the
address box.